Filter Automation
Demand the Ultimate Performance
New and Improved Filter Controllers
All New Features Include:
- Field Programmable Drain Time on Bubble Bead Filter Controllers
- Internal Circuit Breakers allow you to more easily power down the unit
- NEMA 4X Enclosure with Hinged Door for Easy Access and Installation
Features
- Backwash Interval Controlled by Time
- Allows 1 hour to 7 day Backwash Interval
- Fail Safe Operation. If sludge valve fail to close, pump will not turn on after backwash
- Loud 75db Alarm
- One Bottom Manual Override
- Special Mode to Allow you to use your Circulation Pump to Drain your System.
- Easy to Install/Retrofit on to Existing Filters.
- Tried and Tested for Over 5 Years.
| Filter Controller Model | Description |
| ASTPW11 | Propeller Filter Controller |
| ASTPW22 | Propeller Filter By-Pass Controller for use with 3-way actuated ball valves up to 2" |
| ASTPW33 | Propeller Filter By-Pass Controller for use with 3-way actuated ball valves up to 3" or 4" |
| ASTBB14 | Bubble Filter Controller |
| ASTBB1SP5 | Bubble Filter Controller also operates sludge pump. Only operates with Asahi Electric Actuated Valves, includes extra valve limit switch. |
| ASTBBDV26 | Bubble Filter By-Pass Controller. Diverts flow around filter during backwash. |
| ASTBBDV2SP7 | Bubble Filter By-Pass Controller. Diverts flow around filter during backwash. Only operates with Asahi Electric Actuated Valves, includes extra valve limit switch. |
1 Requires one 120v Electric Actuated Ball Valve and two Motor Starters or Pump Start Relays with 110v coils.
2 Requires one 120v Electric Actuated Ball Valve, one 120v Electric Actuated 3-Way Ball Valve 2" or smaller and one Motor Starter or Pump Start Relay with 115v coil.
3 Requires one 120v Electric Actuated Ball Valve, one 120v Electric Actuated 3-Way Ball Valve 3 " or 4" and one Motor Starter or Pump Start Relay with 115v coil.
4 Requires one 120v Electric Actuated Ball Valve. Only requires one Motor Starter or Pump start Relay if the pump is other than 115v, 1-phase or greater than ¾hp 115v 1-phase.
5 Requires one 120v Asahi Electric Actuated Ball Valve with extra limit switch. Only requires one Motor Starter or Pump Start Relay if the pump is other than 115v, 1-phase or greater than ¾hp 115v 1-phase. Does not include sludge pump.
6 Requires two 120v Electric Actuated Ball Valves. One valve to be factory wired, the other AST wired. Does not require Motor Starter or Pump Start Relay since controller does not control the pump.
7 Requires two 120v Electric Actuated Ball Valves. One valve to be factory wired, the other must be AST-wired Asahi Electric Actuated Ball Valve with extra limit switch. Does not require Motor Starter or Pump Start Relay since controller does not control the circulation pump.
Electric Actuated Ball Values |
||
| Spears 120v Electric Actuated Ball Valves | Size/Type | |
| C-E1406-007 | 3/4" (t x t) | |
| C-E1406-010 | 1" (t x t) | |
| C-E1506-012 | 1.25" (t x t) | |
| C-E1506-015 | 1.5" (t x t) | |
| C-E1506-020 | 2" (t x t) | |
| Asahi Electromni 120v Actuated Ball Valves |
Size/Type | |
| AST-206010 | 1" (t x t) | |
| AST-206012 | 1.25" (t x t) | |
| AST-206015 | 1.5" (t x t) | |
| AST-206020 | 2" (t x t) | |
| Spears 120v Electric Actuated Ball Valves | Size/Type | |
| HY3W10ACT | 1" (t x t x t) | |
| HY3W15ACT | 1.5" (t x t x t) | |
| HY3W20ACT | 2" (t x t x t) | |
| HY3W30ACT | 3" (t x t x t) | |
| HY3W40ACT | 4" (t x t x t) | |
Seimens-Furnas Magnetic Motor Starters |
||||
| Motor Starter with 115v coil1 |
Voltage/ Phase |
Hp | Required Heater2 | |
| .5-3MS1151 | 115v / single | .5 | E51 | |
| .75 | E53 | |||
| 1 | E55 | |||
| 1.5 | E60 | |||
| 2 | E61 | |||
| 2.5 | E61 | |||
| 3 | E65 | |||
| .5-3MS2301 | 230v / single | .5 | E51 | |
| .75 | E51 | |||
| 1 | E51 | |||
| 1.5 | E51 | |||
| 2 | E52 | |||
| 2.5 | E51 | |||
| 3 | E54 | |||
| 2-5MS230333 | 230v / three | 2 | E48 | |
| 3 | E52 | |||
| 5 | E54 | |||
| 2-5MS460333 | 460v / three | 2 | E38 | |
| 3 | E42 | |||
| 4 | E44 | |||
| 10MS230333 | 230v / three | 10 | E65 | |
| 10MS460333 | 460v / three | 10 | E54 | |
| E-Series Heater3 | ||||
1 Motor Starts are mounted in NEMA 1 enclosure. Are UL, CSA listed.
2 You must select the appropriate size HEATER to match the amp draw of the motor or pump. Heaters are not included with the motor starter.
3 Three phase motors require THREE heaters. Single phase motor requires ONE heater.
Pump Start Relays |
|||||
| Pump Start Relay with 115v Coil1 |
Pump Motor Hp (MAX) | ||||
Single Phase2 |
Three Phase3 |
||||
| 120v | 230v | 200/230v | 460v | ||
| PSR123-120 | 1 Hp | 2 Hp | 3 Hp | 5 Hp | |
| PSR575-120 | 2 Hp | 5 Hp | 7.5 Hp | 15 Hp | |
1 Contactors are UL and UL Canada rated. Mechanical life up to 10M operations. Gray Noryl Thermoplastic NEMA 4X enclosures of indoor or outdoor use. Gasketed cover. 8 conduit knockouts. Stainless steel screws. Includes sealing plugs to waterproof mounting screws.
2 Single Phase systems require motor overload protection within the motor.
3 Three Phase Systems require either motor overload protection within the motor or external motor overload protection.
1 Contactors are UL and UL Canada rated. Mechanical life up to 10M operations. Gray Noryl Thermoplastic NEMA 4X enclosures of indoor or outdoor use. Gasketed cover. 8 conduit knockouts. Stainless steel screws. Includes sealing plugs to waterproof mounting screws.